The CQLS Illumina NGS sequencing service operates three instruments: NextSeq2000, MiSeq i100 and MiSeq. The CQLS offers library prep and QC services prior to sequencing. Please contact Mark Dasenko with any questions regarding library prep and sequencing submission. Questions regarding the sequencing data output can be addressed by Justin Elser.

Illumina NextSeq2000

Image
NextSeq-ss

More information about the NextSeq 2000 can be found on the specification sheet. There are four different sizes of flow cells available for the NextSeq 2000 that provide the following output:

  • P4- 1.8 billion paired reads/run
  • P3- 1.2 billion paired reads/run
  • P2- 400 million paired reads/run
  • P1- 100 million paired reads/run

The following read lengths are available:

Run Type Run Configuration
P4 300 cycle Paired End 2x150 bp
P4 200 cycle Paired End 2x100 bp
P4 100 cycle Single End 100 bp or Paired End 2x50 bp
P4 50 cycle Single End 50 bp or Paired End 2x25 bp
   
P3 300 cycle Paired End 2x150 bp
P3 200 cycle Paired End 2x100bp
P3 100 cycle Single End 100 bp or Paired End 2x50 bp
   
P2 600 cycle Paired End 2x300 bp
P2 300 cycle Paired End 2x150 bp
P2 200 cycle  Paired End 2x100 bp
P2 100 cycle Single End 100 bp or Paired End 2x50 bp
   
P1 600 cycle Paired End 2x300 bp
P1 300 cycle Paired End 2x150 bp
P1 100 cycle Single End 100 bp or Paired End 2x50 bp

Submit a NextSeq 2000 sequencing request in RELMS.

Illumina MiSeq i100

Image
MiSeq i100

 

More information abou the MiSeq i100 can be found on the specification sheet.  There are two different sizes of flow cells available for the MiSeq i100 that provide the following output:

  • 25M - 25 million paired reads/run
  • 5M - 5 million paired reads/run

The following read lengths are available:

Run Type Run Configuration
25M 1000 cycle Paired End 2x500 bp
25M 600 cycle Paired End 2x300 bp
25M 300 cycle Paired End 2x150 bp
25M 100 cycle Single End 100 bp or Paired End 2x50 bp
5M 600 cycle Paired End 2x300 bp
5M 300 cycle Paired End 2x150 bp

Submit a MiSeq i100 sequencing request in RELMS.

Illumina MiSeq

Ilumina MiSeq

More information about the MiSeq can be found on the specification sheet. There are four different sizes of flow cells available for the MiSeq that provide the following output estimates:

  • v.3 - 25 million paired reads/run (with low diversity amplicon libraries, output will be similar to v.2)
  • v.2 - 15 million paired reads/run
  • v.2 Micro - 4 million paired reads/run
  • v.2 Nano - 1 million paired reads/run

The following read lengths are available:

Run Type Run Configuration
v.3 600 cycle Paired End 2x300 bp
v.3 150 cycle Single End 150 bp or Paired End 2x75 bp
v.2 500 cycle Paired End 2x250 bp
v.2 300 cycle Paired End 2x150 bp
v.2 50 cycle Single End 50 bp or Paired End 2x25 bp
v.2 Micro, 300 cycle Paired End 2x150 bp
v.2 Nano, 500 cycle Paired End 2x250 bp
v.2 Nano, 300 cycle Paired End 2x150 bp

Submit a MiSeq sequencing request in RELMS